Ventilators play a crucial role in maintaining proper air circulation within industrial and commercial spaces. At Faisal Roofing Solution, we offer a range of ventilation solutions designed to enhance airflow efficiency, reduce heat buildup, and improve indoor air quality. Explore our specialized offerings like Louvers, Turbo Ventilators, and Ridge Vents to find the ideal fit for your roofing needs.
Louvers are used to improve air circulation in building and are available in various sizes and different materials.
We are pleased to introduce ourselves as the leading manufacturer of FAISAL SHINE - Turbo Ventilator with matching base plate, which enables the fixing & installation of turbo ventilator very convenient under various site conditions.
FAISAL SHINE - Turbo Ventilator and the matching FAISAL LITE - FRP and PC base plates is technically designed to suit the various site conditions and provide maximum exhaust and rotation of air continuously, hence virtually providing pleasant and fresh air for healthy work environment. Our Turbo Ventilator is so designed having maximum fan blade hence providing optimal exhaust and at the same time is protective towards rain and dust.
DESCRIPTION | FAISAL SHINE - TURBO VENTILATOR | |
---|---|---|
24” | 21” | |
Materia | Aluminium, Stainless Steel (SS - 202 / 304 / 430), Polypropylene (PP) | |
Neck/Throat Dia. | 24" (610mm) | 21" (534mm) |
Outer Dia. | 30" (762mm) | 24" (610mm) |
Overall Height | 21" (534mm) | 13" (330mm) |
Thickness | 0.3 - 0.5 mm | 0.3 - 0.5 mm |
Fins/Vanes |
Width - 85mm, Length - 485mm Thickness-0.3mm, 30-Nos |
Width - 80mm, Length - 380mm Thickness-0.3mm, 24-Nos |
Top Plate | Diameter - 380mm, Thickness - 0.5 mm | Diameter - 350mm, Thickness - 0.5 mm |
No. of bearings | 2 (Sealed Bearing) | 2 (Sealed Bearing) |
Power | Wind Driven | Wind Driven |
Wind Velocity | 1950 Exhauster | 1600 Exhauster |
Temp. Difference (ºC) | 4 to 6. | 3 to 5 |
Stake Height (ft.) | 10 to 30 | 10 to 30 |
Materials: Stainless steel, Aluminium, sealed bearing, fireproofing reinforced, nylon support or metal support and rivet to connect.
Benefits: : Weather resistance and strong fray resistance, fine non-viscidity and self-cleanness, High revolving sensitivity and high air venting efficiency.
Working Conditions: : Temperature difference between indoor and outdoor is 0.45C. It begins to revolve at the wind speed of 0.20 m/s.
Roofing Angle: : Applied in different roof in the scope of 0-22.5 oblique angle.
Applicable scope: : Industrial workshop, warehouse, plants, factories, sheds, commercial and civil building.
Faisal Lite - Fiber-reinforced plastic (FRP) base and Polycarbonate (PC) base plates are used to fix Turbo Ventilators on roofs. We are leading manufacturer of these base plates in matching to all roofing profiles.
Thickness: | 1.5 mm to 2 mm |
Length: | 1700 mm |
Width: | 1080 mm |
Property | Polycarbonate | FRP |
---|---|---|
Impact Resistance | Excellent | Good |
Weather Resistance | Excellent | Poor |
Temperature Resistance | Up to 120 Deg. C | Below 100 Deg. C |
Light Transmission | Up to 89% | Up to 60% |
**Fire Spread | Self-Extinguishing | Flammable |
Thickness | Uniform | Varying |
Maintenance | Easy | Difficult |
*TAC Approval (% of Total Roof Area) | 5% | Only 2% |
Ridge ventilators are ventilators that are installed at the peak of a roof. They can be made either from 0.47mm, 0.50mm or 0.60mm TCT Pre-Painted Galvanized/Galvalume Steel or Bare Galvalume material with Z 90/AZ 150 coating, with wire mesh net. They can be used on industrial warehouses, industrial plants, factory sheds, Industrial building area.
Roofing system ventilators offer a solution to improve ventilation in and out of the building. They are installed on top of the roof and help in controlling interior temperature and humidity by removing excess heat and moisture inside. Effective ventilation helps maintain the indoor condition healthy and prevents issues like mold, condensation, and attic or another roof overheating.
Roof ventilators allow hot air, moisture, and contaminants to escape from the roof space. Natural ventilation allows rising hot air to exit while drawing in cooler air. Wind-driven ventilators like whirlybirds or powered ones mechanically expel air, promoting constant circulation and structural longevity.
Static and ridge ventilators last 15–25 years. Whirlybird and power ventilators last 10–20 years with proper maintenance. Installation quality and material affect lifespan significantly.
Cost depends on type, material, and installation. Static vents are cheaper, while whirlybirds or powered vents are costlier. Faisal Roofing offers competitive pricing and custom quotes.
Faisal Roofing ensures expert, efficient installation.
Yes, they can be retrofitted easily. Faisal Roofing offers affordable solutions tailored to your roof without full replacement.
Contact Faisal Roofing at [insert phone number] or use our website's contact form. Our experts will guide you through every step from evaluation to installation.
Faisal Roofing proudly serves [insert city or region]. We provide services for residential, commercial, and industrial buildings. Contact us to check service availability in your area.